The 48V-650W rectifier is available in a choice of 19” or 23” shelf configurations. Either power system option comes
complete with distribution, controller, and four rectifiers. With 2.6kW total output per shelf, it is an ideal solution to
meet the needs of applications requiring lower power.
Local and remote setup, adjustment, and control are a simple single-step process with Cordex CXC System Controller.
By utilizing TCP/IP technology, complete configuration and monitoring of power equipment is possible
through a network web browser.
SALIENT FEATURES
Convection cooled 2RU module.
19” or 23” shelf mountable, 4 units and 5 units across respec
tively
Active power factor correction >0.99
High efficiency: 91%
Current share bus allows plug-and-play without adjustment
Hot swappable
Weight 1.4 kg
UL, CSA, IEC certified, certified according to UL 60950-1 1st
edition,
Specifications
INPUT SPECIFICATIONS
Input voltage range(120VAC
model)
Input voltage range(100V- 240V
AC model)
Input frequency
Power factor
Input connections
OUTPUT SPECIFICATIONS
Output voltage range
Factory setting
Output current
Output power
Line Regulation
Load Regulation
THD
Wide band noise
Psophometric noise
Output connections
GENERAL CHARACTERISTICS
Efficiency
EMI
Operating temperature
Storage
Humidity
Heat dissipation
Alarms
Cooling
Adjustment
(via CXC Controller)
Protection
Dimensions (HxWxD)
90- 140Vac(output power 650W)
70- 90Vac(derated output power)
176-320Vac(output power is 650W)
90- 176Vac (derated output power)
45-70 Hz
>99%
Dual feed terminal blocks
4- 6mm² (12- 10AWG)
42-58VDC
54.5V
12A @ 54VDC ( 13.5A maximum)
650W at nominal 208-240VAC & 500W at
nominal 120VAC
Static<±0.1%
Dynamic <±1% for any change within rated
limits
Static<±0.5%
Dynamic <±1% for 10-90% load step 2ms
recovery time
< 5%
<10mVrms
< 100mVp-p
<1.0mV
¼” studs on 5/8 “ centers
>91% (1% loss for 120VAC model)
EN55022 class “B”
-40 - 50°C (-40 - 122°F)
(power derated upto 70°C/158°F)
-40 - 85°C (-40 - 185°F)
0- 95%RH non-condensing
<221BTU per hour
Ac mains OK – green LED
Module OK- green LED
Module alarm—red LED
Natural convection
Float and equalize voltage
Battery test voltage
High and low voltage alarms
Current limit
Start delay time
Slope%
Current limit/short circuit
Input /output fuses
Output high voltage shutdown
Output power limiting
Thermal foldback/shutdown
Input transient
AC low line foldback/ shutdown
AC high voltage shutdown
3.4”(88.4mm) x 2.8”(71.6mm) x 9.5”(242mm)
Products & Solutions
Power Interface system
Power Interface system is integrated unit of all functional blocks of BTS site. It is a complete stand-alone BTS site manager.
Telecom Inverters
Our sleek design are parallel operable and redundant telecom inverters facilitates telecommunication and industrial power demands and provide ultimate flexibility for your current and future requirements.
GSM & CDMA Repeaters
We offer complete
range of GSM & CDMA Repeaters, Tower Mount Boosters (TMB) & Tower Mount Amplifiers (TMA).
Telecom Rectifier
We offer full range of Telecom Rectifiers from272W to 350KW Rectifier systems for all Telecommunications need.
All our products are specially designed to work in harsh working conditions, such as wide voltage fluctuations often encountered in developing countries.