Smcel.com :: Enquire :: Register Your Call :: Contact us :: Sitemap
BSMC Power Nigeria Limited BSMC Power Nigeria Limited BSMC Power Nigeria Limited   
Home About us Products & Soluction Career Download Customers
BUSINESS ADDRESS
BSMC POWER Nigeria Limited
3rd Floor- Society of Nigerian Engineers Building,
No.1, Engineering Close,
Off Idowo Taylor Street,
Victoria Island, Lagos (Nigeria)
GSM:+234-8020969082
         +234-8026876251
 
 
BSMC Power Nigeria Limited

Specialized in Supply,Installation, Commissioning & Maintenance of :

Bullet Telecom Rectifier Systems (both for Indoor & outdoor applications)
Bullet Telecom Inverters
Bullet Power Interface & BTS Site Infrastructure Management System (PIS)
Bullet Air-conditioner Controller
Bullet GSM Repeaters / CDMA Repeaters
Bullet Microwave Radios - Licensed / Unlicensed
 
 
BSM I - 1500 W 1U Compact Inverter
  1. Versatile modular design provides flexibility for different power applications
  2. Expandable capacity up to 24KVA with N+1 redundancy configuration
  3. All master” dynamic mechanism eliminates single point failure to optimize reliability
  4. Hot-pluggable operation allows module addition or removal without powering down
  5. High power density and high efficiency (89%)
 
INEX inverter series is an integrated Telecommunication Power System, including inverter, static switch, LCD display controller, and interface modules. With versatile “building block” design and N+1 redundant configuration, the INEX inverter system facilitates complex telecommunication and industrial power demands, and provides ultimate flexibility for your current and future power requirements.
 
N+1 parallel redundancy allows power capacity expandable up to 24KVA. INEX "all master" dynamic mechanism automatically shares and re-organizes critical loads to prevent interruption should any inverter module fail. The DSP-microprocessing controller gives real-time system status through comprehensive LCD display, and allows program settings through the display panel. With a communication interface module installed, you can further control and monitor the system remotely.


BSMC POWER NIGERIA - Leading Manufacturers, Suppliers and Exporters of Telecom Inverters, Telecommunication Power Systems, Telecom Power Monitoring Systems.

[Manufacturers, exporters, suppliers and wholesalers of Telecom Inverters]
 
Inverter Module
INEX inverter module provides pure sine wave AC power output for critical telecommunication equipment. Adopting N+1 redundancy design, INEX Inverter can operate up to 24 units in parallel. INEX inverter module is specially designed with compact size of maximized power density and can reach up to 5.57W/inch3 for INEX 1000 and 8.36W/inch3 for INEX1500. 1U height design allows the module to be installed onto a standard ETSI 300mm Rack. INEX module provides the revolutionary telecom power solution in terms of maximum flexibility and reliability.
Inverter Module
  • Pure sine wave
  • Hot-swap replacement in shelf
  • High efficiency >89%
  • DSP design for higher system reliability
  • Lower audible noise <55dBA
  • Smart fan speed control
  • N+1 redundancy system, load sharing difference < 5%
  • High power density
  • Emergency Power Off function embedded
  • CAN Bus interface embedded
  • -48Vdc Telecom system application
  • Wide operation temperature range, -20˚C to 70˚C

[Manufacturers, exporters, suppliers and wholesalers of Telecom Inverters]

STS Module
INEX STS (Static Transfer Switch) module increases system reliability by automatic power transfer between the inverter output and the AC mains. By setting up the priority of operation mode, users can change the system status of “on line mode” or “off line mode”. The on line mode will keep the input power provided by inverter line and when inverter fails, the line will switch to AC utility line. In off line mode, the system power is always connected to the AC utility line and will switch to inverter power line when AC utility fails. The transfer time is less than 1/4 cycle which prevents the power interruption. The reliable performance of INEX STS module will provide the maximum protection to the connected telecommunication equipment against possible damage caused by the system power failure.
STS Module
  • Universal input range
  • Hot-swap replacement in shelf
  • Back-feed protection
  • Redundant fan design
  • Redundant power supply design
  • Operation Priority Setup of transfer side by setting in Control Module
  • Fast transfer time, typically less than 1/4 cycle
  • Wide operation temperature range, -20˚C to 70˚C
  • Lower audible noise <55dBA
  • Emergency Power Off function embedded
  • No-cross connect
  • Optional maintenance bypass switch function
  • CAN Bus interface embedded
 
Controller Module
INEX controller module allows users to monitor the system status in real time. The superior design enables users to manage the inverter and STS module status including voltage, current, frequency, capacity and temperature. With a user-friendly interface design, users can easily manage the inverter and STS module settings including voltage, frequency, redundancy (for inverter module), and priority (STS module). The controller module can also record the alarm history which can help to understand the operating status while maintaining the system or making further adjustments to improve system performance.
Controller Module
  • CAN Bus protocol for module communication
  • Relay contact output for customized alar ms
  • Hot swappable design
  • Real time clock embedded
  • Comprehensive LCD & LED for status display
  • Audible alarm function

[Manufacturers, exporters, suppliers and wholesalers of Telecom Inverters]

Communication Interface
The communication interface includes several options for wider applications which facilitates the remote managing to the system. The standard ports include relay contacts, RS-232, RS-485, USB. Relay contacts provide five programmable settings to display customized infor mation. RS-232 & USB ports provide the serial connection to PC for software monitoring. RS-485 provides long distance connection for direct monitoring. The optional SNMP offers remote monitoring capability using a browser interface. The communication interface provides powerful monitoring and managing solutions to the system manager.
Communication Interface
  • Relay contacts
  • RS-232
  • RS-485
  • SNMP (Optional)
  • USB
 
Telecom Power Monitoring Software
TelecomPower is a monitoring software which supports either stand alone computer or network connected computers.
TelecomPower Monitoring Software
  • Monitoring to each module in the inverter system in real time.
  • Provides panoramic view of all the related information of utility power, system status, STS status
  • Auto search function with any inver ter power modules in LAN.
  • Password security protection
  • Install and uninstall is easy and clear
 
 Inex System 48V Modular Inverter System

[Manufacturers, exporters, suppliers and wholesalers of Telecom Inverters]

Electrical
Inverter Module
DC input
Nominal voltage: 48VDC
Operating range: 40.5VDC ~ 58VDC
Input protection: Reverse Polarity Protection
Psophometric noise voltage: ≤1.0mV ITU-T O.41 (16.66~6000Hz)
 
AC output
Power Rating: 1000VA/800W, 1500VA/1200W
Waveform: Pure Sine Wave
Power factor: 0.8
Nominal output voltage: 110/115/120Vac, 208/220/230/240Vac
Voltage variation: Max ±2%
Output frequency: 50/60Hz
Crest factor: 3:1 THD: <3%, linear load <5%, non-linear load Efficiency: Min 89%
Isolation AC-Enclosure: Basic isolation (Pri-Gnd) 2121Vdc/1min
Dynamic Response: <±10%
Over Load Protection: 1.5*Inom >20s 1.25*Inom temperature controlled
 
STS Module
Input
Over voltage threshold: Adjustable between
127 to 138Vac for 120Vac systems,
the default value is 132Vac
233 to 252Vac for 220Vac systems,
the default value is 242Vac
Under voltage threshold: Adjustable between
100 to 114Vac for 120Vac systems,
the default value is 108Vac
176 to 209Vac for 220Vac systems,
the default value is 198Vac
Backfeed Protection: Comply with safety requirement
Redundant Power: Startup power-on by priority
Design: Source or alternative
   
Output  
Nominal Output Voltage: Same as utility or the output of Inverter modules
Permissible Frequency Area: Max. +/-2.5% (inverter synchronization)
Transfer Time: Typical 1/4cycle
Rated Power: 50A for 110/115/120Vac & 208/220/230/240Vac
Operation Methods: Inverter priority/Mains priority
 
 Environmental
Operating Temperature: - -20°C to 70°C (-4° to 158°F) -5°C to 58°C (23° to 122°F)
with full performance
Storage Temperature: -40°C to +85°C (-40° to 185°F)
Humidity: 90% Relative Humidity (non condensing)
Audible Noise: 55dB
 
Controller Module
Input  
Nominal voltage: 48VDC
Operating range: 30VDC ~ 72VDC
Over Current Protection: 2A Fuse
   
Human Interface  
LCD: Resolution (Line X Array) 4 X 16 Charactor
LED Indicator: 3 colored indicators for normal, warning and fault display
Alarm: Audio alarm when inverter, STS, controller module operate abnormally
   
System Parameter  
BaudRate: Setting controller com port baud rate
Keypad tones: Setting keypad tones
Time & Date: Setting current time and date
Setting Password: Setting system password
Brightness: Setting LCD brightness
Default: Change current system parameters to default value
Battery Calibration: Calibration battery voltage
 
Mechanical
Inverter Module  
Dimension  
   mm: 270D x 215W x 43.8H
   inches: 10.63D x 8.46W x 1.72H
   Weight: 2.5kg (5.5lb)
STS Module  
Dimension  
   mm: 270D x 215W x 43.8H
   inches: 10.63D x 8.46W x 1.72H
   Weight: 2.0kg (4.4lb)
Controller Module  
Dimensions (D x W x H):  
   mm: 277D x 87.9W x 43.5H
   inches: 10.9D x 3.46W x 1.71H
   Weight: 1.0kg (2.2lb)
Hot-swap Chassis  
19/23” mounting brackets
Inverter Chassis
Dimension
 
   mm: 320D x 440W x 44H
   inches: 12.6D x 17.32W x 1.73H
   Weight: 2.5kg (5.5lb)
STS & Controller Chassis  
Dimension  
   mm: 320D x 440W x 44H
   inches: 12.6D x 17.32W x 1.73H
   Weight: 3.4kg (7.5lb)
 
Communication Interface
RS-232×1: Communicate with PC
RS-485×2: Communicate with supervision
Dry Contact×5: Communicate with external Monitor
USB×1: Communicate with PC
 
Standards
UL, CE, RoHS
 
 
 
Products & Solutions
Power Interface system Power Interface system
Power Interface system is integrated unit of all functional blocks of BTS site. It is a complete stand-alone BTS site manager.
Read More
1.0	Telecom Rectifier Telecom Inverters
Our sleek design are parallel operable and redundant  telecom inverters facilitates telecommunication and industrial power demands and provide ultimate flexibility for your current and  future requirements.
Read More
Router GSM & CDMA Repeaters

We offer complete range of GSM Repeaters& CDMA Repeaters, Tower Mounted Boosters (TMB) & Tower Mount Amplifiers (TMA).

Read More
1.0	Telecom Rectifier Telecom Rectifier
We offer full range of Telecom Rectifiers from272W to 350KW Rectifier systems for all Telecommunications need.
Read More
Telecom Rectifier Systems manufacturers | Telecom Rectifier Systems Suppliers | Telecom Rectifier Systems Exporters | DC Power Plants manufacturers | CDMA Repeaters Suppliers | CDMA Repeater Manufacturers | RF Repeaters | GSM Repeaters | GSM Repeaters Manufacturers | Microwave Radios | Site Infrastructure Solutions | Power Interface Systems (PIS) | Site Infrastructure & Power Management System | BTS Power Management Systems | BTS Power Optimization Solutions | CAPEX Saving | Power Interface Unit | Tower Mounted Boosters (TMB) | Tower Mount Amplifiers (TMA) | Air-conditioner Controller Unit | Telecom Inverter Suppliers | Telecom Inverter Manufacturers | Parallel Operation Inverters


All our products are specially designed to work in harsh working conditions, such as wide voltage fluctuations often encountered in developing countries.
Home :: About Us :: Products & Soluction :: Career :: Download :: Customers
Copyright © 2007 SMCEL. All rights reserved. Site best viewed in 800x600 resolution .
Home About Us Products & Soluction Career Download Customers